вернуться: 2023-01-09
magnetic-type
linear-motion
measuring stroke 50mm
with/without spring return device
long life expectancy (up to 50 million movements)
mechanical stroke
approx.51mm
mass
approx.200g
protection degree
ip40
operating force (with spring return)
approx.2n-8n
stopper strength
approx.9kgf
life expectancy
50,000,000 reciprocating motions
housing material
anodized aluminium alloy
shaft material
stainless steel
operating temperature range
-30℃~ 85℃
storage temperature range
-30℃~ 85℃
esd durability
contact discharge ±8kv,aerial discharge ±15kv,en61000-4-2:2009
ems durability
10v/m (80mhz~1ghz,1khz80% amplitude modulation),en61000-4-3:2006 a1:2010
standard model
hcl25-50-r-0505(for more input voltage/output signal such as 2410、2405、2442, please check our catalog.)
input voltage
5v±10%
output signal
0~100%vcc
current consumption (no-load)
<16ma
output deviation at both ends
<1%·vcc
load resistance
>100kω
electrical stroke
50±0.5mm
independent linearity tolerance
±0.5%
resolution
4096 (12 bit)
update rate
0.3ms
0505
5v±10% / 0~100%vcc
2410
15~30v / 0~10v
2405
9~30v / 0~5v
2442
15~30v / 4~20ma
special input and output
available for other input and output, such as 1010: 10v input, 0-10v output, 0305: 3.3v input, 0-5v output, etc.
special shaft
special length of shaft、special diameter(<6mm) or special machining on shaft etc.
special electrical stroke
available for special electrical stroke (<50mm).
special operating force
available for special operating force.